Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int. j. cardiovasc. sci. (Impr.) ; 31(2): f:143-l:151, mar.-abr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-882060

RESUMO

Background: Few studies have used portable gas analyzers during the 6-minute walk test (6MWT) in patients with heart failure and normal ejection fraction (HFNEF). Objectives: To analyze the kinetics of hemodynamic, ventilatory, and metabolic variables in patients with HFNEF during the T6m using a portable gas analyzer. Methods: Prospective, analytical study with an intentional, non-probabilistic, convenience sample. In total, 24 patients with HFNEF and past hospital admissions due to a clinical diagnosis of heart failure (HF) were included using the 2007 criteria established by the European Society of Cardiology. Three assessments were performed: 6MWT familiarization, 6MWT with the portable gas analyzer, and cardiopulmonary exercise test (CPET). Results: The heart rates (HRs) and the peak VO 2 at the end of the 6MWT corresponded to 85.7% and 86.45% of the values obtained during the CPET. The final HRs after the T6m were equivalent to those obtained at the CPET anaerobic threshold (AT), with relative VO 2 values at the end of the 6MWT above the VO 2 of the CPET AT. There was no difference between the maximum respiratory quotient (RQ) values in these two tests, which were both above 1.0. The VE/VO 2 slope descended initially and then ascended significantly after the fifth minute of the test, estimating the identification of the AT. Conclusions: In patients with HFNEF, the 6MWT represents an almost maximum effort, and is performed above the CPET AT and 85% above the maximum HR and the CPET peak VO 2 , with a maximum RQ similar to that in the CPET


Fundamentos: Poucos estudos utilizaram analisadores de gases portáteis no teste da caminhada de seis minutos (T6m) em portadores de insuficiência cardíaca com fração de ejeção normal (ICFEN). Objetivos: Analisar a cinética das variáveis hemodinâmicas, ventilatórias e metabólicas utilizando analisador de gases portátil em portadores de ICFEN durante o T6m. Métodos: Estudo prospectivo, analítico, com amostra não probabilística, intencional e por conveniência. Foram estudados 24 pacientes portadores de ICFEN com passado de internação por clínica de insuficiência cardíaca (IC), incluídos pelos critérios da European Society of Cardiology 2007. Realizaram-se três avaliações: T6m de aprendizado, T6m com o analisador de gases portátil e teste de esforço cardiopulmonar (TECP). Resultados: As frequências cardíacas (FC) e o consumo de oxigênio (VO 2 ) pico ao final do T6m corresponderam a 85,7% e 86,45% dos valores obtidos no TECP. As FC finais no T6m foram equivalentes às obtidas no limiar anaeróbio (LA) do TECP, com valores de VO 2 relativo ao final do T6m acima do VO 2 no LA do TECP. Não houve diferença entre os valores máximos do quociente respiratório (QR) entre os dois testes, ambos acima de 1,0. A curva de VE/VO 2 demonstrou descenso com posterior ascensão significativa após o quinto minuto de teste, estimando-se a identificação do LA. Conclusões: Para pacientes com ICFEN, o T6m representa um esforço quase máximo, sendo executado acima do LA do TECP e acima dos 85% da FC máxima e do VO 2 pico do TECP, com QR máximo semelhante ao do TECP


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Gasometria/métodos , Exercício Físico , Insuficiência Cardíaca , Volume Sistólico , Teste de Caminhada/métodos , Índice de Massa Corporal , Doença da Artéria Coronariana , Diabetes Mellitus , Dislipidemias , Hipertensão , Obesidade , Estudos Prospectivos , Fatores de Risco , Interpretação Estatística de Dados
2.
Arq. bras. cardiol ; 106(5): 358-366, May 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-784181

RESUMO

Abstract Background: More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. Objectives: To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Methods: Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO2). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. Results: After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO2 and 123I-MIBG scintigraphic parameters. Conclusion: Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.


Resumo Fundamento: Mais de 50% dos pacientes com insuficiência cardíaca têm fração de ejeção preservada (ICFEN). A cintilografia marcada com iodo 123 com metaiodobenzilguanidina (123I-MIBG) e o teste cardiopulmonar do exercício (TCPE) são marcadores de prognóstico da ICFEN. O nebivolol é um betabloqueador com propriedade vasodilatadora. Objetivos: Avaliar o impacto da terapia com nebivolol sobre as variáveis da cintilografia com 123I-MIBG e do TCPE em pacientes com ICFEN. Métodos: Vinte e cinco pacientes realizaram cintilografia com 123I-MIBG para avaliar a taxa de washout e a relação coração/mediastino precoce e tardia. Durante o TCPE, foi analisado o comportamento da pressão arterial sistólica (PAS), frequência cardíaca (FC) durante o esforço e a recuperação (FCR) e o consumo de oxigênio (VO2). Após avaliação inicial, separamos nossa amostra em grupos controle versus intervenção, iniciamos o nebivolol e repetimos os exames após 3 meses. Resultados: Após o tratamento, o grupo intervenção apresentou melhora na PAS (149 mmHg [143,5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0,016]), FC em repouso (78 bpm [65,5-84 bpm] versus 64,5 bpm [57,5-75,5 bpm, p = 0,028]), PAS no pico do esforço (235 mmHg [216,5-249 mmHg] versus 198 mmHg [191-220,5 mmHg], p = 0,001), FC no pico do esforço (124,5 bpm [115-142 bpm] versus 115 bpm [103,7-124 bpm], p = 0,043) e FCR no 1º minuto (6,5 bpm [4,75-12,75 bpm] versus 14,5 bpm [6,7-22 bpm], p = 0,025) e no 2º minuto (15,5 bpm [13-21,75 bpm] versus 23,5 bpm [16-31,7 bpm], p = 0,005), porém não apresentou mudança no VO2 de pico e nos parâmetros da cintilografia com 123I-MIBG. Conclusão: Apesar de um melhor controle da PAS e na FC em repouso e durante o esforço e uma melhora na FCR, o nebivolol não ocasionou efeito positivo sobre o VO2 de pico e nos parâmetros da cintilografia com 123I-MIBG. A ausência de efeito sobre a atividade adrenérgica pode ser a causa da falta de efeito sobre a capacidade funcional.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Vasodilatadores/uso terapêutico , Compostos Radiofarmacêuticos , 3-Iodobenzilguanidina , Nebivolol/uso terapêutico , Insuficiência Cardíaca/fisiopatologia , Consumo de Oxigênio/efeitos dos fármacos , Volume Sistólico/fisiologia , Pressão Sanguínea/fisiologia , Cintilografia , Estudos Prospectivos , Teste de Esforço/métodos , Agonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/diagnóstico por imagem , Radioisótopos do Iodo
3.
Rev. bras. med. esporte ; 20(1): 41-46, Jan-Feb/2014. tab, graf
Artigo em Português | LILACS | ID: lil-704728

RESUMO

INTRODUÇÃO: O teste de esforço cardiopulmonar (TECP) fornece dados que orientam tratamento, prognóstico e tomadas de decisões. Entretanto, seu uso na insuficiência cardíaca de fração de ejeção normal (ICFEN) ainda não está bem esclarecido, em especial considerando novas variáveis que vêm despontando. OBJETIVOS: Comparar o comportamento das principais variáveis diagnósticas e prognósticas do TECP entre dois grupos: pacientes com insuficiência cardíaca de fração de ejeção reduzida (ICFER) e pacientes com ICFEN. MÉTODOS: Foram avaliados 36 pacientes com insuficiência cardíaca em classe funcional II-III da NYAH: 20 com ICFEN e 16 com ICFER do ambulatório de insuficiência cardíaca do Hospital Universitário Antônio Pedro (UFF). Os pacientes do Grupo ICFER selecionados foram os com FE < 35% e os do grupo ICFEN seguiram os critérios diagnósticos da Sociedade Europeia de Cardiologia de 2007. Realizou-se TECP, em esteira com protocolo de rampa, com analisador de gases VO2000. Foram aplicados teste t de Student, Mann-Whitney, teste de Fisher, modelo linear generalizado e de Cochran-Mantel-Haenszel para as análises estatísticas. RESULTADOS: O grupo ICFEN apresentou níveis mais elevados da pressão arterial em repouso, na resposta ao esforço, na potência circulatória e ventilatória, além de um maior tempo de recuperação da cinética do consumo de oxigênio. Não houve diferença em relação a outras variáveis prognósticas do TECP para o grupo ICFER. CONCLUSÕES: A pressão arterial de repouso e em esforço, a potência circulatória e ventilatória e a cinética de recuperação do VO2 (T1/2) foram as variáveis que apresentaram maior ...


INTRODUCTION: The cardiopulmonary exercise testing (CPX) provides data that guide treatment, prognosis and decision making. However its use in heart failure with normal ejection fraction (HFnEF) is still not all clear, especially considering new variables that are emerging. OBJECTIVE: To compare the behavior of key diagnostic and prognostic variables of CPX testing between two groups; patients with heart with reduced ejection fraction of (HfrEF) and those with HFnEF). METHODS: 36 patients with heart failure were evaluated in Nyah functional class II-III: 20 with HFnEF and 16 patients with HFrEF at the Hospital Universitário Antônio Pedro (UFF). The patients from HFrEF group were those with EF<35%, and those from the HFnEF group follow the diagnostic criteria of the European Society of Cardiology 2007. CPX was performed on a treadmill with a ramp protocol, with gas analyzer VO2000. The Student t test, Mann-Whitney test and Fisher, generalized linear model and the Cochran-Mantel-Haenszel test for statistical analysis were applied. RESULTS: The HFnEF group presented higher levels of blood pressure at rest, higher response to exertion, higher circulatory and ventilatory power, and longer recovery kinetics of oxygen uptake. There was no difference in relation to other prognostic variables of CPX in the HFrEF group. CONCLUSIONS: The blood pressure at rest and during exercise, the circulatory and ventilatory capacity and the kinetics of VO2 (T1/2), were the variables that showed the highest discriminative value between the two populations by CPX. .


INTRODUCCIÓN: La prueba de esfuerzo cardiopulmonar (PECP) suministra datos que orientan tratamiento, pronóstico y tomas de decisiones. No obstante, su uso en la insuficiencia cardíaca de fracción de eyección normal (ICFEN) todavía no está bien aclarado, en especial, considerando nuevas variables que vienen apareciendo. OBJETIVOS: Comparar el comportamiento de las variables principales de diagnóstico y de pronóstico de la PECP, entre dos grupos: pacientes con insuficiencia cardíaca de fracción de eyección reducida (ICFER) y pacientes con ICFEN. MÉTODOS: Se evaluaron 36 pacientes con insuficiencia cardíaca en clase funcional II-III de la NYAH: 20 con ICFEN y 16 con ICFER del dispensario de insuficiencia cardíaca del Hospital Universitário Antonio Pedro (UFF). Los pacientes del grupo ICFER fueron seleccionados con FE <35% y el grupo ICFEN siguieron los diagnósticos de la Sociedad Europea de Cardiología 2007 criterios. Se realizó la PECP, en estera con regulador de rampa, con analizador de gases VO2000. Se aplicaron las pruebas t de Student, Mann-Whitney, prueba de Fisher, modelo linear generalizado y de Cochran-Mantel-Haenszel para los análisis estadísticos. RESULTADOS: El grupo ICFEN presentó niveles más altos de presión arterial en reposo, en la respuesta al esfuerzo, en las potencias circulatoria y ventilatoria, además de un tempo más prolongado de recuperación de la cinética del consumo de oxígeno. No hubo diferencia en relación con otras variables de pronóstico de la PECP para el grupo ICFER. CONCLUSIONES: La presión arterial de reposo y en esfuerzo, las potencias circulatoria y ventilatoria y la cinética de recuperación del VO2 (T1/2) fueron las variables que presentaron más valor discriminativo entre los grupos según la PECP. .

4.
Arq. bras. cardiol ; 100(5): 395-403, maio 2013. graf, tab
Artigo em Português | LILACS | ID: lil-675607

RESUMO

FUNDAMENTO: Na insuficiência cardíaca, níveis de interleucina 1β (IL 1β) se associam a prognóstico. A atividade adrenérgica cardíaca avaliada através da cintilografia com metiodobenzilguanidina (I123 MIBG) e parâmetros do exercício são importantes preditores de prognóstico. A relação entre essas variáveis não está bem definida. OBJETIVO: Avaliar associação entre níveis de IL 1β com parâmetros do exercício e do I123 MIBG. MÉTODOS: Estudo observacional transversal, com avaliação de 25 pacientes consecutivos com insuficiência cardíaca e fração de ejeção menor que 45%, através de: dosagem de IL 1β; parâmetros do I123 MIBG [relação coração/mediastino precoce e tardia, taxa de washout (WO)]; e teste ergométrico em esteira pelo protocolo de Rampa. RESULTADOS: Separados em dois grupos pelos níveis de IL 1β (normal vs. elevado), o grupo com níveis aumentados apresentava menor reserva de duplo produto (RDP), menor capacidade funcional (CF) e recuperação mais lenta da frequência cardíaca no 1º (RFC 1º) e 2º minuto (RFC 2º), e maior WO. Na análise univariada, todas as variáveis se correlacionaram com a IL 1β; RDP: r = 0,203, p = 0,024; CF: r = 0,181, p = 0,034; RFC 1º: r = 0,182, p = 0,034; RFC 2º: r = 0,204, p = 0,023; WO: r = 0,263, p = 0,009. Na multivariada, apenas a WO permaneceu com correlação significativa (r2 = 0,263, p = 0,009). CONCLUSÃO: A hipertonia adrenérgica foi o principal determinante dos níveis de IL 1β, demonstrando que a atividade simpática excessiva influencia a atividade inflamatória sistêmica. As variáveis do teste ergométrico não foram capazes de identificar pacientes com níveis elevados de IL 1β.


BACKGROUND: Interleukin 1β (IL 1β) levels are associated with prognosis in heart failure. The cardiac adrenergic activity as assessed by metaiodobenzylguanidine (I123 MIBG) scintigraphy along with exercise parameters are important predictors of prognosis. The relationship between these variables is not fully established. OBJECTIVE: To evaluate the association of IL 1β levels with exercise and I123 MIBG parameters. METHODS: Cross-sectional observational study evaluating 25 consecutive patients with heart failure and ejection fraction lower than 45% by means of: determination of IL 1β levels; I123 MIBG parameters [early and late heart/mediastinum ratio, washout rate (WO)]; and treadmill exercise test using the ramp protocol. RESULTS: The patients were divided into two groups according to their IL 1β levels (normal vs. increased). The group with increased levels showed lower double-product reserve (DPR); lower functional capacity (FC); slower heart rate recovery at the first (HRR 1º) and second minute (HRR 2º); and higher WO. In the univariate analysis, all variables correlated with IL 1β; DPR: r = 0.203, p = 0.024; FC: r = 0.181, p = 0.034; HRR 1º: r = 0.182, p = 0.034; HRR 2º: r = 0.204, p = 0.023; WO: r = 0.263, p = 0.009. In the multivariate analysis, only WO maintained a significant correlation (r² = 0.263, p = 0.009). CONCLUSION: Adrenergic overactivity was the main determinant of IL 1β levels, thus demonstrating that an excessive sympathetic activity influences the systemic inflammatory response. Exercise test variables were not able to identify patients with high IL 1β levels.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Esforço/métodos , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Interleucina-1beta/sangue , Volume Sistólico/fisiologia , Métodos Epidemiológicos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca , Prognóstico , Compostos Radiofarmacêuticos
5.
Rev. bras. cardiol. (Impr.) ; 26(1): 40-44, jan.-fev. 2013. tab
Artigo em Português | LILACS | ID: lil-679829

RESUMO

Fundamentos: A insuficiência cardíaca desencadeia limitações físicas e psicológicos que alteram consideravelmente a qualidade de vida do paciente. entre os sintomas físicos, destacam-se a fadiga e s dispnéia que possuem agravamento progressivo nessa ssíndrome. Objetivo: Identificar os diagnósticos de enfermagem mais frequentes encontrados em pacientes com insuficiêcia cardíaca relacionando-os com a alteração da qualidade devida apresentada. Métodos: Foram recrutados 17 pacientes consecutivos com IC sistólica (fração de ejeção do ventrículo esquerdo (FEVE)

Background: Heart failure results in physical and psycholigical constraints that downgrade the quality of life for patients to a considerable extent. Outstanding among the physical symptoms are fatigue and dyspnea, which worsen steadily with this syndrome. Objetive: To identify the nursing diagnoses found most frequently for patients with heart failure, related to changes in the presented quality of life. Methods: Seventeen consecutive patientswith systolic HF (left ventricular ejection fraction (LVEF)

Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Diagnóstico de Enfermagem/métodos , Diagnóstico de Enfermagem , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Qualidade de Vida , Fatores de Risco
6.
Arq. bras. cardiol ; 98(5): 398-405, maio 2012. graf, tab
Artigo em Português | LILACS | ID: lil-643639

RESUMO

FUNDAMENTO: Frequência Cardíaca de Recuperação (RFC) reflete a capacidade do sistema cardiovascular de reverter a supressão vagal ocasionada pelo exercício. A cintilografia com metaiodobenzilguanidina (I¹²³ MIBG) avalia a inervação e ativação adrenérgica cardíaca. A associação entre esses dois métodos não está bem esclarecida. OBJETIVO: Avaliar associação entre RFC e Taxa de "Washout" (WO) de I¹²³ MIBG em pacientes com Insuficiência Cardíaca (IC). MÉTODOS: Vinte e cinco pacientes com fração de ejeção < 45% realizaram teste ergométrico, sendo analisada a variação da RFC do 1º ao 8º minuto pós-esforço. Submetidos a I¹²³ MIBG foram separados em grupos pela WO: G1) < 27% e G2) > 27%. Para análise estatística, foi utilizado teste U de Mann Whitney e o coeficiente de correlação de Spearman. RESULTADOS: G2 demonstrou uma variação mais lenta da RFC: 1º minuto: G1: 21,5 (16,12 - 26,87) vs G2: 11,00 (8,5 - 13,5) bpm, p = 0,001; 2º minuto: G1: 34 (29 - 39) vs G2: 20 (14 - 26) bpm, p = 0,001; 3º minuto: G1: 46 (37,8 - 54,1) vs G2: 30 (22 - 38) bpm, p = 0,005; 5º minuto: G1: 51,5 (42 - 61) vs G2: 39 (31,5 - 46,5) bpm, p = 0,013; e no 8º minuto: G1: 54,5 (46,5 - 62,5) vs G2: 43 (34 - 52) bpm, p = 0,037. A RFC no 1º (r = -0,555; p = 0,004), e 2º minuto (r = -0,550; p = 0,004) apresentaram correlação negativa com WO. CONCLUSÃO: Pacientes com IC e WO elevado apresentaram uma RFC anormal em comparação com pacientes com WO normal. Tais achados sugerem que a ativação adrenérgica pode influenciar na RFC.


BACKGROUND: Heart Rate Recovery (HRR) reflects the capacity of the cardiovascular system to reverse the vagal withdrawal caused by exercise. Scintigraphy with metaiodobenzylguanidine (I¹23 MIBG) evaluates innervation and cardiac adrenergic activation. The association of these two methods is not well established. OBJECTIVE: To evaluate the association between HRR and washout rate (WO) of I¹²³ MIBG in patients with heart failure (HF). METHODS: wenty-five patients with ejection fraction < 45% underwent exercise testing, and analysis of the variation of HRR from the 1st to the 8th minute after exertion. Submitted to I¹²³ MIBG, they were separated into groups by WO: G1) <27% and G2) > 27%. For the statistical analysis Mann-Whitney's U test and Spearman's correlation coefficient were used. RESULTS: G2 showed a slower variation of HRR: 1st minute: G1: 21.5 (16.12 to 26.87) vs. G2: 11.00 (8.5 to 13.5) bpm, p = 0.001; 2nd minute: G1: 34 (29-39) vs. G2: 20 (14 - 26) bpm, p = 0.001; 3rd minute: G1: 46 (37.8 - 54.1) vs. G2: 30 (22 - 38) bpm, p = 0.005; 5th minute: G1: 51.5 (42 - 61) vs. G2: 39 (31.5 to 46.5) bpm, p = 0.013, and in the 8th minute: G1: 54.5 (46.5 - 62.5) vs. G2: 43 (34 - 52) bpm, p = 0.037. HRR in the 1st (r = -0.555, p = 0.004), and in the 2nd minute (r = -0.550, p = 0.004) were negatively correlated with WO. CONCLUSION: Patients with high HF and WO showed an abnormal HRR compared with patients with normal WO. These findings suggest that adrenergic activation may influence the HRR.


Assuntos
Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Estudos Transversais , Teste de Esforço , Insuficiência Cardíaca , Coração , Compostos Radiofarmacêuticos , Estatísticas não Paramétricas , Fatores de Tempo
7.
Arq. bras. cardiol ; 96(5): 370-376, maio 2011.
Artigo em Português | LILACS | ID: lil-587653

RESUMO

FUNDAMENTO: Na insuficiência cardíaca, o teste ergométrico (TE) avalia capacidade funcional, um determinante de prognóstico. A cintilografia com I¹²³ MIBG mostra a ativação simpática cardíaca. OBJETIVO: Avaliar a associação entre as variáveis do TE e as alterações da cintilografia com I¹²³ MIBG. MÉTODOS: Foram submetidos 23 pacientes (FEVE < 45 por cento) à cintilografia com I¹²³ MIBG e separados em: G1) taxa de Washout < 27 por cento; G2) > 27 por cento. Esses pacientes realizaram TE, onde foram analisadas: pressão arterial sistólica no pico do esforço (PASP), frequência cardíaca no pico do esforço (FCP), variação da pressão arterial sistólica intraesforço (Δ PAS), reserva cronotrópica e capacidade funcional em METs. Utilizaram-se para a análise estatística, o teste t de Student ou o teste U de Mann-Whitney, o coeficiente de Spearman e o coeficiente de regressão linear. RESULTADOS: A PASP (G1: 181,00 ± 28,01; G2: 153,27 ± 27,71, p = 0,027), a Δ PAS [G1: 64 (47,5-80,5); G2: 36 (25-47) mmHg, p = 0,015], a FCP (G1: 136,91 ± 19,66; G2: 118,45 ± 13,98 bpm, p = 0,018), a reserva cronotrópica (G1: 70,42 ± 17,94; G2: 49,47 ± 14,89 por cento, p = 0,006) e a capacidade funcional [G1: 8,37 (6,47-10,27); G2: 4,42 (2,46-6,38) METs, p = 0,003] foram menores no G2. Houve correlação negativa entre taxa de Washout com PASP (r = -0,505, p = 0,014), Δ PAS (r = -0,493, p = 0,017) e capacidade funcional (r = -0,646, p = 0,001). Após regressão linear, PASP (r = -0,422, p = 0,016) e capacidade funcional (r = -0,804, p = 0,004) foram associadas com taxa de Washout. CONCLUSÃO: Em pacientes com insuficiência cardíaca, PASP e capacidade funcional foram as varáveis mais associadas com a taxa de Washout.


BACKGROUND: The exercise treadmill test can be used in ventricular dysfunction patients for functional capacity or predicting prognosis. The cardiac image with 123I MIBG shows cardiac sympathetic activation. OBJECTIVE: To evaluate the relationship between exercise treadmill test variables and cardiac image changes in 123I MIBG. METHODS: 23 patients with LVEF < 45 percent performed scintigraphy cardiac with 123I MIBG and divided into two groups. G1: Washout rate < 27 percent; G2: > 27 percent. Systolic blood pressure (SBP), heart rate (HR) and functional capacity were evaluated. It was performed Student t test or Mann-Whitney U test, Spearman coefficient and linear regression. RESULTS: SBP at exercise peak (G1: 181.00 ± 28.01; G2: 153.27 ± 27.71 mmHg, p = 0.027), SBP variation [G1: 64(47.5-80.5); G2: 36(25-47) mmHg, p = 0.015], the HR at exercise peak (G1: 136.91 ± 19.66; G2: 118.45 ± 13.98 bpm, p = 0.018) and chronotropic response (G1: 70.42 ± 17.94; G2: 49.47 ± 14.89 percent, p = 0.006), and functional capacity [G1: 8.37(6.47-10.27); G2: 4.42(2.46-6.38) METs, p = 0.003] were smaller in G2 group. There was negative correlation between Washout rate and SBP at exercise peak (r = -0.505, p = 0.014), variation in SBP (r = -0.493, p = 0.017) and functional capacity (r = -0.646, p = 0.001). Nevertheless, SBP at exercise peak (r = -0.422, p = 0.016) and functional capacity (r = -0.804, p = 0.004) were the only variables associated with Washout rate, after linear regression. CONCLUSION: In heart failure patients, the SBP at exercise peak and functional capacity were the variables associated with Washout rate.


FUNDAMENTOS: En la Insuficiencia Cardíaca, la Ergometría (Test Ergométrico - TE) evalúa la capacidad funcional, un determinante de pronóstico. El centellograma con I¹²³ MIBG muestra la activación simpática cardíaca. OBJETIVO: Evaluar la asociación entre las variables del TE y las alteraciones del centellograma con I¹²³ MIBG. MÉTODOS: Se sometieron 23 pacientes (FEVI < 45 por ciento) a centellograma con I¹²³ MIBG y se separaron en: G1) tasa de Washout < 27 por ciento; G2) > 27 por ciento. Estos pacientes realizaron TE, en el que se analizaron: presión arterial sistólica en el pico del esfuerzo (PAS P), frecuencia cardíaca en el pico del esfuerzo (FCP), variación de la presión arterial sistólica intraesfuerzo (Δ PAS), reserva cronotrópica y capacidad funcional en MET. Para el análisis estadístico se utilizaron el test t de Student o el test U de Mann-Whitney, el coeficiente de Spearman y el coeficiente de regresión lineal. RESULTADOS: La PAS P (G1: 181,00 ± 28,01; G2: 153,27 ± 27,71, p = 0,027), la Δ PAS [G1: 64 (47,5-80,5); G2: 36 (25-47) mmHg, p = 0,015], la FCP (G1: 136,91 ± 19,66; G2: 118,45 ± 13,98 lpm, p = 0,018), la reserva cronotrópica (G1: 70,42 ± 17,94; G2: 49,47 ± 14,89 por ciento, p = 0,006) y la capacidad funcional [G1: 8,37 (6,47-10,27); G2: 4,42 (2,46-6,38) MET, p=0,003] fueron menores menores en el G2. Hubo una correlación negativa entre la tasa de Washout con PASP (r = -0,505, p = 0,014), Δ PAS (r = -0,493, p = 0,017) y capacidad funcional (r = -0,646, p = 0,001). Después de la regresión lineal, PASP (r = -0,422, p = 0,016) y capacidad funcional (r = -0,804, p = 0,004) se asociaron con la tasa de Washout. CONCLUSIÓN: En pacientes con insuficiencia cardíaca, la PASP y la capacidad funcional fueron las variables más asociadas con la tasa de Washout. (Arq Bras Cardiol 2011;96(5):370-376).


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Esforço/métodos , Insuficiência Cardíaca , Coração , Compostos Radiofarmacêuticos , Pressão Sanguínea/fisiologia , Tolerância ao Exercício/fisiologia , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Modelos Lineares , Estatísticas não Paramétricas
8.
Rev. bras. cardiol. (Impr.) ; 23(4): 244-250, jul.-ago. 2010. ilus, graf
Artigo em Português | LILACS | ID: lil-568764

RESUMO

O teste de esforço é um método não invasivo de grande aplicabilidade clínica na cardiologia. Seu uso, atualmente, não mais se limita ao diagnóstico de doença arterial coronariana devido à grande variedade de informações que o teste revela. A associação de alterações clínicas, hemodinâmicas e metabólicas com as alterações eletrocardiográficas ampliaram o poder não só diagnóstico, mas, especialmente o poder prognóstico do método. Mais recentemente, a avaliação do comportamento do sistema nervoso autonômico, durante o exercício dinâmico, tem mostrado grande valor em cardiopatias graves, como na insuficiência cardíaca. O objetivo desta revisão é descrever como os novos parâmetros do teste de esforço podem ser utilizados para avaliar o sistema nervoso autonômico em pacientes com insuficiência cardíaca e descrever suas implicações prognósticas.


A non-invasive method with ample clinicalapplication in cardiology, stress testing is no longer limited to diagnosing coronary artery disease, due to the broad range of information that it provides. Associating changes in clinical, metabolic and hemodynamic responses with electrocardiographic alterations has extended its diagnostic and prognosticcapacities. More recently, evaluating the behavior of the autonomic nervous system during dynamic exercise has proven extremely valuable for severecardiovascular diseases, such as heart failure. This paper describes how new stress test parameters may be deployed to evaluate the autonomic nervoussystem in heart failure patients, in addition to describing its prognostic implications.


Assuntos
Animais , Disautonomias Primárias/complicações , Disautonomias Primárias/diagnóstico , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Teste de Esforço/métodos , Teste de Esforço
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA